Current transformer calculation examples

Chapter 3 the unidirectional current pulse transformer with 46 diode rectification and natural resetting 3. A current transformer ct is a type of transformer that is used to reduce or multiply an alternating current ac. Sizing current transformers for line protection applications. For example, a 75kva transformer with a 208y120 secondary and 5% impedance has a capacity of 208 amps. In part 3, well intuitively understand current transformer ratio, what it means, how to calculate it, and how to use it in ct calculations. The current transformer will operate into either a short circuit or a resistive load until the voltage induced is enough to. Rating of a single phase transformer in kva kva v x i rating of a three phase transformer. Apr 16, 2011 current transformers principle of operation of ct. A current transformer is defined as as an instrument transformer in which the secondary current is substantially proportional to the primary current under normal conditions of operation and differs in phase from it by an angle which is approximately zero for an appropriate direction of the connections. The ferromagnetic core, or a core made from a permanent magnet, of a transformer also uses thin electrically insulated slices so that these surfaces can decrease resistance for the current that passes from the primary coils to the secondary coils of the transformer. Enter the primary and secondary transformer voltages. Enter the transformer rating and select the appropriate unit. Current 200a rms, turns ratio transformer current 200 200ma rms. In a current transformer its primary winding is connected in series with the line carrying the load current.

The transformer is an electrical device that allows to increase or decrease the voltage in an alternating current electrical circuit, maintaining the power. A 3 phase transformer has three magnetic circuits that are interlaced to give a uniform distribution of the. To increasedecrease the alternating volts in electric power, transformers are used. In the transformer, the effect of the mutual inductance is to cause the primary ciruit to take more power from the electrical supply in response to an increased load on the secondary. The basics of current transformers nk technologies. Rarely, if ever, is it necessary to determine the phaseangle error of a ct used for relaying. A protective current transformer type 5p10 has, for example, the accuracy class 5p and the rated accuracy limit factor 10. The current transformer produces a current proportional to the current flowing though its magnetic circuit. This is not necessary on transformers below 15kva, thus why ul does not require the impedance on the nameplate of transformers below 15kva. So perhaps you are really asking how to measure the ratio. It produces a current in its secondary which is proportional to the current in its primary.

An online three phase transformer calculator to find the current in different power units. This quick calculation can help you determine the fault current on the secondary of a transformer for the purpose of selecting the correct overcurrent protective devices that can interrupt the available fault current. In case of a 20005a class 1 5va current transformer. Jul 11, 2017 as your circuit indicates, the ratio is simply 6005120. How we can calculate burden of current transformer. How to determine the ratio of a current transformer quora.

Single phase transformer fullload current amps kva. A current transformer operates with a set primary current and will try to output a constant current to the load, independent of the load. Lets next explore the impact of adding in the utility available fault current. These connections determine the way the transformer will behave, and they also determine the methods of calculation required for properly applying a given transformer. Consider a ct with the following specification and protection requirements. Transformer current calculator calculate transformer.

Accuracy decreases with increased burden load or low line current. In an ideal transformer ignoring any losses, the power available in the secondary winding will be the same as the power in the primary winding, they are constant wattage devices and do not change the power only the voltage to current ratio. Each video part 1 for example takes approximately 10 hours to complete which. Calculating shortcircuit current including utility available fault. Dec 22, 2017 this physics video tutorial provides a basic introduction into transformers. Stepup, stepdown, and isolation transformers worksheet ac. Concept of current transformer with examples current transformer c. Per unit calculation per unit system examples electrical. Using the transformers rated values of apparent power and secondary voltage, s base 700 mva. Transformer calculator kva calculator full load amps calculator. To determine which ct is appropriate for a particular application, it is important to understand the. The core components of a transformer are the two coils, primary and secondary, that wrap around an iron core. You can determine the full load amps of a transformer with the following formula.

Click on the calculate button to obtain the results. In sizing cts the conductor size and distance is important. It has two types, single phase and three phase transformer. Selecting current transformers janitza electronics. Current transformer circuits for power electronics applications. An example of calculating transformer size and voltage drop. As your circuit indicates, the ratio is simply 6005120.

At a given flux magnitude, the core saturates, the excitation current increases disproportionally, and the secondary current is no longer an accurate replica of the primary current. The primary winding which consists of a single turn passing through the ct toroidal core is connected in series with the shunt inductor rated 69. Transformer rated secondary current is calculated by dividing the rated kva capacity by the rated secondary voltage. C classified current transformers ct have fully distributed windings and hence core. The current transformer function is different than that of a voltage transformer. The secondary winding of ct has large number of turns which is determined by the secondary. The primary winding of ct consists of very few turns usually 1. Transformer short circuit current calculation and solutions. A current transformer ct is used to measure current in a shunt inductor connected on a 120 kv network. Large current through fuse which will cause it to blow, little current through secondary winding or load, little voltage across secondary winding or load.

The rules presented are generally used and apply, for example, to protection calculation of spacom and red 500 series protection relays. The calculated resistance is then multiplied by the square of the ct. How do you calculate the maximum possible available fault. The transformer calculator uses the following formulas. Concept of current transformer with examples paktechpoint. Transformer current calculator when connecting a transformer to an electrical power source, you need to calculate the current, it will draw through the primary. A quick calculation for the maximum fault current at the transformer secondary terminals is fc fla %pu z fc 1202 0. Electrical tutorial about current transformer basics and current transformer. The proportion of the current in the cable that you get in the transformer is equal to the turns ratio. Below are two simple formulas to find the rating of single phase and three phase transformers. This physics video tutorial provides a basic introduction into transformers. No current through any component, no voltage across any secondaryside component.

A transformer has 200 turns on its primary coil, and 50 on its secondary coil. Calculation and analysis of transformer inrush current based on parameters of transformer and operating conditions electronics and elect rical engineering. Here we will cover six important aspects of using instrument transformer in the power system. Here voltage drop is within limit and motor full load current. Current transformer white paper the basics of current transformers ratio the ct ratio is the ratio of primary current input to secondary current output at full load. This means the current level is stepped down 5 times where, if the primary current is 200 amps, the ct output is 40 amps. When using wiring material with a nominal crosssectional area of 1. While some colleagues prefer to remember formulas or factors, i prefer to resolve the problem step by step using basic principles.

The transformer is the most common application of the concept of mutual inductance. What is the rated secondary current of a 30kva singlephase transformer with a rated secondary voltage of 240 volts. Transformer capacity calculator three phase transformer. Transformer configuration names like and derive from the way the windings are connected inside the transformer. The current transformer primary is connected in series with the device in which the current is to be measured. The power that enters the equipment, in the case of an ideal transformer, is equal to that obtained at the output. Deltaconnected transformers have the windings of three singlephase transformers connected in series with each.

Easy and simple methods for calculating short circuit curr. Thus, in an ideal transformer the power ratio is equal to one unity as the voltage, v multiplied by. C classified current transformers ct have fully distributed windings and hence core leakage flux has negligible effect on the ratio. Its reactances per unit to the machines own base are x s 2 and the time constants are s4. You should then hook the transformer up to a circuit breaker of an equal or higher current rating so that the breaker will not trip under normal operation of the transformer. Pdf calculation and analysis of transformer inrush current. How to calculatefind the rating of transformer in kva. Current transformer saturation voltage disturbance.

Current transformer basics and the current transformer. The calculation of current in a three phase system has been brought up on our site feedback and is a discussion i seem to get involved in every now and again. There is no obligation to choose the transformers ratings as the base values, but it is an option. Current transformer equivalent circuit model part 1a. Voltage drop at transformer secondary due to motor inrush vd 1688 17391 10% voltage drop at transformer secondary is 10% which is within permissible limit. Improper sizing of current transformers or long secondary conductor runs with undersized cable can result in poor.

Consider a threephase transformer with a rating of 700 mva and a secondary voltage of 145 kv. Based on the infinite source method at the primary of the transformer. Ct accuracy a ct is most accurate at rated current with a low burden load. Determine the shortcircuit current isubsc at the transformer s secondary terminals per its impedance. Current transformers, along with voltage or potential transformers, are instrument transformers. Since current transformer is fundamentally a transformer, it translates the current from the pecondary side, rimary to the s inversely proportional to the turns so. Calculation of the current transformer accuracy limit factor. It explains how to calculate the voltage, current, and power in the primary coil and the secondary coil given the. Instrument transformers are special types of transformers intended to measure cur rents and voltages. Determine the shortcircuit current isubsc at the transformers secondary terminals per its impedance. Whilst measurement current transformers are intended to reach saturation point as quickly as possible once they exceed their operational current range expressed by the overcurrent factor fs in order to avoid an increase in the secondary current with a fault e. The following examples illustrate the rated secondary current calculation. If you need assistance with circuit protection devices such as fuses or breakers, or wire sizing, please consult a licensed electrical contractor or electrician in your area who will be familiar with state and local codes. How to calculate transformer turns ratio sciencing.

546 20 1548 852 982 1005 483 661 270 491 1039 267 815 1451 628 730 531 1309 1148 1516 188 164 929 1142 309 1409 180 1035 264 738 830 335 429 994